A garage was built to keep a car dry, not a person warm. Walk into most integral garages in Bristol in November and you'll feel it: a bare concrete slab, single-skin walls, a roof with nothing in it and a metal door. Garage conversion insulation is what turns that shell into a room you'd want to sleep or work in. Here's each part in the order we'd tackle it, with the numbers building control checks.
Why garages are cold
Four things, usually all at once:
- The floor is a concrete slab, often with no insulation and sometimes no damp-proof membrane, and lower than the house floor.
- The walls are often a single skin of brick or block, with no cavity to stop rain or cold.
- The roof is a flat roof or a pitched roof with an uninsulated ceiling, or no ceiling at all.
- The door is a large opening that will become a new wall.
The numbers: what Approved Document L asks for
Turning a garage into a heated room is what Approved Document L calls a change to energy status, and it uses a garage conversion as its example. Existing walls, floor and roof that are being kept should be upgraded where they're worse than a threshold. Anything new must meet the standard for new elements.
| Element | Existing, upgraded (Table 4.3) | New (Table 4.2) |
|---|---|---|
| Floor | 0.25 | 0.18 |
| Wall, insulated inside or out | 0.30 | 0.18 |
| Wall, cavity filled | 0.55 | 0.18 |
| Roof | 0.16 | 0.15 |
| Windows and doors | 1.4 |
All figures are maximum U-values in W/m²K. The lower the number, the warmer the element. Approved Document L allows a lesser standard in some cases, for example where wall insulation would cut the room's floor area by more than 5%, or where meeting the figure isn't technically feasible or wouldn't pay back within 15 years. Your building control body decides. Our guide to garage conversion building regulations covers the rest of what they check.
The floor: damp first, then insulation
Insulation laid over a damp slab just gets wet. So the first question on any garage floor is whether there's a damp-proof membrane, and whether it links up with the damp-proof course in the walls.
There are three common ways to build the new floor:
- Membrane, rigid insulation and a floating floor. A new damp-proof membrane over the slab, lapped up to meet the DPC, then rigid insulation boards, then moisture-resistant chipboard. It's quick, and the build-up usually brings the floor close to house level.
- A timber joisted floor. Joists on sleepers over the slab, insulation between them, boarded on top. Useful where the slab is well below the house floor and there's height to make up.
- Insulation and screed. Membrane and insulation, then a screed. It suits underfloor heating, but the screed needs drying time.
Whichever route, watch the house's own floor. Many older houses have a suspended timber floor ventilated through air bricks, and some of those vents pass through or into the garage. Approved Document C sets ventilation for a suspended floor at not less than 1,500 mm² per metre run of external wall or 500 mm² per m² of floor, whichever is greater, and allows offset periscope vents or pipes at least 100 mm across where levels are tight. A conversion must keep that airflow, usually by ducting it through the new floor to an outside wall. Block it and you risk damp and rot under the house.
Walls: lining a single-skin garage
A single-skin wall can let rain through, so check it's weathertight first: pointing, render, gutters and the DPC. Then there are two options for the lining:
- An insulated stud wall, built a little off the masonry, with insulation between the studs, a vapour control layer on the warm side and plasterboard. It handles uneven walls and piers and makes room for cables.
- Insulated plasterboard bonded to the wall. Thinner, and fine on a dry, true wall. Not a good idea on a wall that gets damp.
The new wall where the door was
The garage door opening becomes a new wall, usually with a window. It's a new element, so it has to meet 0.18 W/m²K, which normally means a cavity wall with insulation, tied into the old walls and the DPC.
It also needs something to stand on. A garage door opening often has no proper foundation under it, just a threshold. Building control will want to see what's there, and a new footing is common. If the converted room becomes a bedroom, our guide to turning a garage into a bedroom covers the window, escape and layout.
The roof: flat or pitched
Flat roof. The best upgrade is usually a warm deck: insulation laid on top of the roof deck with a new waterproof membrane over it, so the timbers stay warm. A cold deck, with insulation between the joists, needs a ventilated gap above it to stay dry. Our flat roof extensions guide explains both build-ups.
Pitched roof. Insulate at ceiling level, between and over the joists, and keep the roof space ventilated. If you want the room to open up into the roof, insulate at the rafters instead, as you would in a loft. Our loft conversion insulation guide covers rafter insulation in detail.
Cold bridges and condensation
Cold bridges are the places heat sneaks round the insulation. In a garage conversion they gather at:
- the junction between the new floor and the walls
- the reveals and lintel of the old door opening
- the eaves, where wall insulation meets roof insulation
Each is a spot where warm room air meets a cold surface and condenses. Insulation has to run continuously round those junctions, and the room needs ventilation that works: trickle vents and, for a shower room, an extract fan.
Cost, time and living at home
Our garage conversions start from £10,000 plus VAT. The floor, wall lining and roof upgrade each appear as their own line in a detailed, itemised quote, and the price only changes if you agree the change first.
A garage conversion is one of the easier projects to live with. Most of the work happens behind the old garage door; the noisy part is breaking through to the house, if you're adding a doorway. Site hours are 8am to 5pm, Monday to Friday. Whether the finished room adds value depends on what it becomes; our article asking does a garage conversion add value weighs it up, and our garage conversion service explains how we run them.
Frequently asked questions
What U-values does a garage conversion need?
Under Approved Document L, existing elements being kept should be upgraded to about 0.25 for the floor, 0.30 for walls insulated inside or out, and 0.16 for the roof. New elements, such as the wall where the door was, must meet 0.18, and new windows 1.4 W/m²K.
Do I need to raise the floor in a garage conversion?
Usually the new floor build-up raises it most of the way anyway. A damp-proof membrane, rigid insulation and a floating chipboard floor take up height. Where the slab is much lower, a timber joisted floor makes up the difference. Matching the house level avoids a step.
Can I use insulated plasterboard on garage walls?
On a dry, straight wall, yes. On a single-skin wall that might get damp, an insulated stud wall built slightly off the masonry, with a vapour control layer, is usually the safer choice. Make sure the wall is weathertight first.
Does the new wall in a garage conversion need foundations?
Usually. The old door opening often has only a threshold under it, not a proper footing. Building control will want to see what's there, and a new foundation is common before the cavity wall goes up.
How much does it cost to convert a garage?